Thiết bị đo độ cứng
Share on Social Networks
Share Link
Use permanent link to share in social mediaShare with a friend
Please login to send this presentation by email!
Embed in your website
2. 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345 1 234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234 5 1 234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234 5 1 234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234 5 1 234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234 5 1 234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234 5 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345 HI 3812 HARDNESS TEST KIT 5 5 5 5 5 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 1 1 1 1 1 5 mL sample 50 mL sample
1. Instruction Manual www.hannainst.com Dear Customer, Thank you for choosing a Hanna Product. Please read the instructions carefully before using the chemical test kit. It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. Each kit is supplied with: • Reagent 1, 1 bottle with dropper (30 mL); • Reagent 2, 1 bottle with dropper (10 mL); • Reagent 3, 1 bottle (120 mL); • 2 beakers (10 mL and 50 mL); • 1 graduated syringe. Note: Any damaged or defective item must be returned in its original packing materials. HI 3812 Hardness Test Kit ISTR3812 09/99 PRINTED IN ITALY In history, water hardness was defined by the capacity of water to precipitate soap. The ionic species in the water causing the precipitation was later found to be primarily calcium and magnesium. In the present, therefore, water hardness is actually a quantitative measure of these ions in the water sample. It is also now known that certain other ion species, such as iron, zinc and manganese, contribute to the overall water hardness. The measure and subsequent control of water hardness is essential to prevent scaling and clogging in water pipes. The Hanna hardness test kit makes monitoring easy, quick and safe. The compact size provides the versatility to use the kit anywhere. The design makes the kit easy to handle and, except for Reagent 3, practically prevents accidental injury or damage due to spills. Range 0 to 30 mg/L (ppm) CaCO 3 0 to 300 mg/L (ppm) CaCO 3 Smallest Increment 0.3 mg/L [in the 0-30 mg/L range] 3 mg/L [in the 0-300 mg/L range] Analysis Method EDTA titration Sample Size 5 mL and 50 mL (average) Number of Tests 100 (average) Case Dimensions 200x120x60 mm (7.9x4.7x2.4") Shipping Weight 460 g (1 lb.) SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SIGNIFICANCE AND USE SIGNIFICANCE AND USE SIGNIFICANCE AND USE SIGNIFICANCE AND USE SIGNIFICANCE AND USE CHEMICAL REACTION CHEMICAL REACTION CHEMICAL REACTION CHEMICAL REACTION CHEMICAL REACTION The hardness level as mg/L (ppm) calcium carbonate is deter- mined by an EDTA (ethylene-diamine-tetraacetic acid) titration. The solution is first adjusted to a pH of 10 using a buffer solution. The indicator chelates with metal ions such as mag- nesium or calcium to form a red colored complex. As EDTA is added, metal ions complex with it. After all the free metal ions have been complexed, an excess EDTA removes the metal ions complexed with the indicator to form a blue colored solution. This color change from red to blue is the endpoint of the titration. READ ALL THE INSTRUCTIONS BEFORE USING THE TEST KIT LOOK AT THE BACK PAGE FOR THE ILLUSTRATED PROCEDURE Note: Push and twist pipet tip into tapered end of syringe ensuring an air-tight fit. HIGH RANGE – 0 to 300 mg/L CaCO 3 • Remove the cap from the small plas- tic vessel. Rinse the plastic vessel with the water sample, fill to the 5 mL mark and replace the cap. • Add 5 drops of Reagent 1 through the cap port and mix carefully swirling the vessel in tight circles. INSTRUCTIONS INSTRUCTIONS INSTRUCTIONS INSTRUCTIONS INSTRUCTIONS • Add 1 drop of Reagent 2 through the cap port and mix as described above. The solution becomes a red-violet color. • Take the titration syringe and push the plunger completely into the syringe. Insert tip into Re- agent 3 and pull the plunger out until the lower edge of the seal is on the 0 mark of the syringe. • Place the syringe tip into the cap port of the plastic vessel and slowly add the titration solu- tion dropwise, swirling to mix after each drop. Continue adding the titration solution until the solution becomes purple, then mix for 15 sec- onds after each additional drop until the solution turns blue. • Read off the milliliters of titration solution from the syringe scale and multiply by 300 to obtain mg/L (ppm) CaCO 3 . LOW RANGE – 0 to 30 mg/L CaCO 3 If result is lower than 30 mg/L, the precision of the test can be improved by following the steps below. • Remove the cap from the large plastic vessel. Rinse it with the water sample, fill to the 50 mL mark and replace the cap. • Proceed with the titration as for the high range test. • Read off the milliliters of titration solution from the syringe scale and multiply by 30 to obtain mg/L (ppm) CaCO 3 . x 300 = mg/L CaCO 3 x 30 = mg/L CaCO 3 REFERENCES REFERENCES REFERENCES REFERENCES REFERENCES Standard Methods for the Examination of Water and Waste- water, 16 th Edition, 1985, p. 210-214. 1987 Annual Book of ASTM Standard, vol. 11.01 Water (1), p. 212-215. HEALTH AND SAFETY HEALTH AND SAFETY HEALTH AND SAFETY HEALTH AND SAFETY HEALTH AND SAFETY The chemicals contained in this test kit may be hazardous if improperly handled. Read Health and Safety Data Sheets before performing the test.
Views
- 6289 Total Views
- 5171 Website Views
- 1118 Embeded Views
Actions
- 0 Social Shares
- 0 Likes
- 0 Dislikes
- 0 Comments
Share count
- 0 Facebook
- 0 Twitter
- 0 LinkedIn
- 0 Google+
Embeds 2
- 7 ineet.com.vn
- 1 ineet.nextgerp.com